D3973 Rev COperators ManualFort Atkinson, Wisconsin USADigi-Star InternationalPannigen, The Netherlandswww.digi-star.comJune 3, 2014
10 Moisture TrackerTM Operators Manual D3973 Rev COPERATIONInstall USB DriveBefore turning on device, install USB drive in USB port. See page 11. USB
11Moisture TrackerTM Operators ManualD3973 Rev CUSB drive connected to USB portTo turn on Moisture TrackerTM, depress the Power button for 2 seconds.P
12 Moisture TrackerTM Operators Manual D3973 Rev CMAIN MENUReach Main Menu home display by pressing . Use and arrows then button for menus. See
13Moisture TrackerTM Operators ManualD3973 Rev CMOISTURE MEASUREMENTSelect Measurement press Information on farms and ingre-dients are rst entered in
14 Moisture TrackerTM Operators Manual D3973 Rev CSee Notes below.Press Trigger or Number of trigger presses neces-sary for a moisture measurement is
15Moisture TrackerTM Operators ManualD3973 Rev CFarmer Settings• For initial setup of the Mois-ture TrackerTM, go to main menu by pressing the key.
16 Moisture TrackerTM Operators Manual D3973 Rev C• Press or , or press to enter a pass-word of 4 characters mini-mum. • Press X to erase any
17Moisture TrackerTM Operators ManualD3973 Rev CSelect Set Date And Time• Press or arrows to move yellow triangle. • Press or arrows to chang
18 Moisture TrackerTM Operators Manual D3973 Rev CSet Power Down TimeSet Screen Dim TimeSelect Set Power Down Time Press Select Set Screen Dim Time pr
19Moisture TrackerTM Operators ManualD3973 Rev CSet Defogger LevelSelect Set Defogger Level press • Set Defogger Level to pre-vent moisture from cond
2 Moisture TrackerTM Operators Manual D3973 Rev CFollow the link below to a video on Digi-Star’s web site showing how to use Moisture TrackerTM.digi-s
20 Moisture TrackerTM Operators Manual D3973 Rev CCalibrate SensorFor accurate measurements, the device must be calibrated using the calibration disk
21Moisture TrackerTM Operators ManualD3973 Rev CSelect Calibrate Sensor press NOTE: Sensor calibration is also a main menu option.• Make sure the si
22 Moisture TrackerTM Operators Manual D3973 Rev C• If a warning appears, verify cleanliness of probe head.• Press 2 while holding white disk agains
23Moisture TrackerTM Operators ManualD3973 Rev CSet Worker Operating Mode• Use or select Set Operating Mode• Press • From Farmer Main M
24 Moisture TrackerTM Operators Manual D3973 Rev CSet Worker Options• From Farmer Main Menu Select Set Worker Option• Press • Press or to sele
25Moisture TrackerTM Operators ManualD3973 Rev CPREVIOUS READINGSUse or arrow keys select Previous Readings, press • Use or arrow keys selec
26 Moisture TrackerTM Operators Manual D3973 Rev CAll previous measurements are displayed for that farm. Use or arrows to scroll screen• Press an
27Moisture TrackerTM Operators ManualD3973 Rev C• Press to save device information to USB drive.• Press to cancel• Press to highlight OK
28 Moisture TrackerTM Operators Manual D3973 Rev CSET LANGUAGESelect Set Language, press • Press or to select language.• Press To return to prev
29Moisture TrackerTM Operators ManualD3973 Rev CMOISTURE TRACKERTM INFORMATIONBatteriesMoisture TrackerTM uses a rechargeable battery pack located in
3Moisture TrackerTM Operators ManualD3973 Rev CCONTENTSLINKS ...2M
30 Moisture TrackerTM Operators Manual D3973 Rev CHOW TO UPDATE MOISTURE TRACKERTMSOFTWARE (HAND-HELD DEVICE)There are 3 parts to the Moisture Tracker
31Moisture TrackerTM Operators ManualD3973 Rev CUpdate Calibration List and DLL5. Select latest software revision.6. Select “Download”.7.
32 Moisture TrackerTM Operators Manual D3973 Rev C10. Select “Safely Remove Hardware” 11. Select “Eject Mass Storage” 12. Remove US
33Moisture TrackerTM Operators ManualD3973 Rev CLICENSEA temporary license is included with the Moisture TrackerTM. A 1 year license is included with
34 Moisture TrackerTM Operators Manual D3973 Rev CThis Page Intentionally Blank
4 Moisture TrackerTM Operators Manual D3973 Rev CMOISTURE TRACKERTM FEATURESMoisture TrackerTM determines percentage of moisture in ingredi-ents fed t
5Moisture TrackerTM Operators ManualD3973 Rev C Do not take moisture measurements from open face of a feed bunk over 8 feet high due to risk of silage
6 Moisture TrackerTM Operators Manual D3973 Rev CTriggerProbe GrateBatteryin handleCharging Port
7Moisture TrackerTM Operators ManualD3973 Rev CSlide lock back to open USB drive coverThis port forfactory useUSB driveport for data transferUSB drive
8 Moisture TrackerTM Operators Manual D3973 Rev C
9Moisture TrackerTM Operators ManualD3973 Rev CNumberDescription Function/Use/Operation1 Power Button Turns Moisture TrackerTM on/off2 Home Press to r